21. ARM 服务器更新固件¶
更新固件可以解决lscpu显示不正确问题,如socket和cache大小。
21.1. 更新之前¶
root@ubuntu:~# lscpu
Architecture: aarch64
Byte Order: Little Endian
CPU(s): 64
On-line CPU(s) list: 0-63
Thread(s) per core: 1
Core(s) per socket: 4
Socket(s): 16
NUMA node(s): 4
Vendor ID: ARM
Model: 2
Model name: Cortex-A72
Stepping: r0p2
BogoMIPS: 100.00
NUMA node0 CPU(s): 0-15
NUMA node1 CPU(s): 16-31
NUMA node2 CPU(s): 32-47
NUMA node3 CPU(s): 48-63
Flags: fp asimd evtstrm aes pmull sha1 sha2 crc32 cpuid
root@ubuntu:~#
21.2. 更新之后¶
root@ubuntu:~# lscpu
Architecture: aarch64
Byte Order: Little Endian
CPU(s): 64
On-line CPU(s) list: 0-63
Thread(s) per core: 1
Core(s) per socket: 32
Socket(s): 2
NUMA node(s): 4
Vendor ID: ARM
Model: 2
Model name: Cortex-A72
Stepping: r0p2
BogoMIPS: 100.00
L1d cache: 32K
L1i cache: 48K
L2 cache: 1024K
L3 cache: 16384K
NUMA node0 CPU(s): 0-15
NUMA node1 CPU(s): 16-31
NUMA node2 CPU(s): 32-47
NUMA node3 CPU(s): 48-63
Flags: fp asimd evtstrm aes pmull sha1 sha2 crc32 cpuid
root@ubuntu:~#
21.3. 更新办法¶
查看当前固件版本
浏览器iBMC界面→系统管理→更新固件
Primary Partition Image Version : 2.45
Backup Partition Image Version : 2.40
BIOS Version : 1.34
CPLD Version : 1.05
到服务器官网下载新版本固件,例如:
网址
需要下载iBMC,BIOS,CDLP三个压缩包。 解压后在浏览器界面
浏览器iBMC界面→系统管理→更新固件
依次上传,并点击升级,每个固件升级需要几分钟,升级成功会有提示。
升级成功后
Primary Partition Image Version : 3.22
Backup Partition Image Version : 2.45
BIOS Version : 1.58
CPLD Version : 1.05
CPLD升级不成功,是因为服务器版本太低。